|    Home    |    Visit KPROKOREA.COM    |    Contact Us

 Products

  Safe-Mate
  - Download Catalogue

  Safe Drive2
  - Download Catalogue

  CA-2000
  CA-2000S
  CA-2010
  CA-05FS
  CA-10FL
  CA-10FS
  CA-20F
  CA-20FL
  CA-20FS
  - Download Catalogue

  AL-1100
  AL-2500
  AL-2500elite
  AL-2500prime
  AL-2600
  AL-3100
  AL-3500
  AL-4000
  AL-5500
  AL-6000
  AL-6000lite
  AL-6000P
  AL-7000
  AL-9000
  AL-9000P
  AL-9010
  ALX-1000
  EBS
  - Download Catalogue

 

 


   Safe-Mate Deluxe


 

 

safe mate

[ Personal Alcohol Detector ]

 

  CALIBRATION

You need to calibrate the analyzer before use.

1. Press the calibration (CAL) button under LCD for 1~2 seconds and release it. The C-A-L-1    appears on the display in sequence. Then numeral on the display counts down 5 to 0 with    WAIT flashing on the display. While the 0 stays on the display, blow into the inhaler for 3~4    seconds within 2cm. Exhale a sonsistent amount of air each time and at the same angle.
   BLOW flashes. (1st Calibration)

2. After 1st calibration, C-A-L-2 appears in sequence on the display. Then, the analyzer starts    count down from 9 to 1 this time. Finally, 0 appears. Depending on the condition of the    analyzer, A-D-J might appear on the display in sequence and restart count down from 5 or 9.

3. While the 0 stays on the display, blow into the inhaler for 3~4 seconds within 2cm. Exhale a    consistent amount of air each time and at the same angle. BLOW flashes. (2nd calibration)
   The display goes off.

For calibration as gas leakage tester, follow above steps but do not blow your breath into analyzer but just keep it in the air.

  OPERATION

1. Press the power button under LCD for 1~ 2 seconds and release it. The display counts down
    from 5 to 0, with WAIT flashing. Depending on the condition of the analyzer, A-D-J might
    appear on the display in sequence then the analyzer starts count down from 5 or 9.

2. When 0 appears, a beep sounds. Blow into the inhaler for 3~4 seconds. Exhale a consistent
    amount of air each time and at the same angle. BLOW flashes.

3. The test result appears with beep sound. Then the power turns off automatically after 10        seconds.
    Press the power button one more, you can turn off the analyzer when you want.

To check gas leakage, just leave the unit where you want to check instead of blowing into the unit. To obtain more accurate result, we recommend you to check repeatedly two or three times.

  INSTALLING THE BATTERIES

Your analyzer requires two AAA batteries. We recommend alkaline batteries.

1. Slide open the battery compartment cover on the back of the unit.

2. Install two AAA batteries, observing the polarity (+ and - ) marked inside
   Close the battery compartment cover.

3. If the battery is discharged, the character “L” appears on the LCD display and blinks 10 times      with beep sound, then should change the battery.

  IMPORTANT NOTICE

  • Because the sensor reference is changed depends on temperature and humidity, it is good idea to calibrate every 2 weeks more than once before using this breath analyzer.
  • Use this breath analyzer by allowing at least 30 minutes after consuming alcohol. This ensures the breath sample is taken from your lungs, not from the alcohol in your mouth, which may result in a higher reading.
  • Because the sensor is highly sensitive, the unit will not function correctly if it is wet or damaged. Keep the unit in a secure, clean and dry place at room temperature.
  • Generally alcohol sensor can be affected by temperature or humidity. Therefore, it could happen the allowable margin of error.
  • Each individual’s body responds uniquely to the consumption of alcohol. A person’s ability to drive may become legally impaired at a point below the legal blood alcohol limit.
  • Blood alcohol content changes as the time passes and measurement might be affected by environment conditions such as temperature and humidity. The analyzer is designed to be used as a reference measure only to aid in promoting reasonable driving: it should not be used in anticipation of the use or operation of vehicles, machinery, or equipment. The analyzer makes no references whatsoever to blood alcohol contents or other such measures of intoxication promulgated by government, medical, or other agencies or bodies.

 SPECIFICATION

  • Power Source : Two "AAA" batteries
  • Battery Life : More than 800 measurement
  • Sensor Type : MEMS Semiconductor Gas Sensor
  • Dimensions : 90 x 30 x 17 (mm)
  • Weight : 43g (Including Batteries)

 

 CARE

Keep the Breath Analyzer dry; if it gets wet, wipe it dry immediately.
Use and store the Breath Analyzer only in normal temperature environments.
Handle the Breath Analyzer carefully; do not drop it.
Keep the Breath Analyzer away from dust and dirt, and wipe it with a damp cloth occasionally to keep it looking new.

Modifying or tampering with the analyzer’s internal components can cause a malfunction and might invalidate its warranty.

 

 

 

 

 

 

 

 

 

      Copyright(c) Alcoholdetector.co.kr  All rights reserved. Contact Webmaster for more information.