Products |
|
|
|
|
|
|
|
Safe-Mate Deluxe
|
|
|
|
[
Personal Alcohol Detector ] |
|
|
CALIBRATION |
You need to calibrate the analyzer before use.
1. Press the calibration (CAL) button under LCD for
1~2 seconds and release it. The C-A-L-1 appears on
the display in sequence. Then numeral on the display
counts down 5 to 0 with WAIT flashing on the display.
While the 0 stays on the display, blow into the inhaler
for 3~4 seconds within 2cm. Exhale a sonsistent amount
of air each time and at the same angle. BLOW flashes.
(1st Calibration)
2. After 1st calibration, C-A-L-2 appears in sequence
on the display. Then, the analyzer starts count down
from 9 to 1 this time. Finally, 0 appears. Depending
on the condition of the analyzer, A-D-J might appear
on the display in sequence and restart count down
from 5 or 9.
3. While the 0 stays on the display, blow into the
inhaler for 3~4 seconds within 2cm. Exhale a consistent
amount of air each time and at the same angle. BLOW
flashes. (2nd calibration) The display goes off.
For calibration as gas leakage tester, follow
above steps but do not blow your breath into analyzer
but just keep it in the air. |
|
|
|
OPERATION |
1. Press the power button under LCD for 1~ 2 seconds and release it.
The display counts down
from 5 to 0, with WAIT flashing.
Depending on the condition of the analyzer, A-D-J might
appear on the display in sequence
then the analyzer starts count down from 5 or 9.
2. When 0 appears, a beep sounds. Blow into the inhaler
for 3~4 seconds. Exhale a consistent
amount of air each time and at
the same angle. BLOW flashes.
3. The test result appears with beep sound. Then the
power turns off automatically after 10
seconds.
Press the power button one more,
you can turn off the analyzer when you want.
To check gas leakage,
just leave the unit where you want to check instead
of blowing into the unit. To obtain more accurate
result, we recommend you to check repeatedly two or
three times.
|
|
|
|
INSTALLING THE BATTERIES |
Your analyzer requires two AAA batteries. We recommend alkaline batteries.
1. Slide open the battery compartment cover on the
back of the unit.
2. Install two AAA batteries, observing the polarity
(+ and - ) marked inside
Close the battery compartment cover.
3. If the battery is discharged, the character “L”
appears on the LCD display and blinks 10 times
with beep sound, then should change the battery.
|
|
|
|
IMPORTANT NOTICE |
- Because the sensor reference is changed depends on temperature and humidity,
it is good idea to calibrate every 2 weeks more than once before using this breath analyzer.
- Use this breath analyzer by allowing at least 30 minutes after consuming
alcohol. This ensures the breath sample is taken from your lungs, not from the alcohol in your mouth,
which may result in a higher reading.
- Because the sensor is highly sensitive, the unit will not function correctly
if it is wet or damaged. Keep the unit in a secure, clean and dry place at room temperature.
- Generally alcohol sensor can be affected by temperature or humidity. Therefore,
it could happen the allowable margin of error.
- Each individual’s body responds uniquely to the consumption of alcohol.
A person’s ability to drive may become legally impaired at a point below the legal blood alcohol limit.
- Blood alcohol content changes as the time passes and measurement might
be affected by environment conditions such as temperature and humidity. The analyzer is designed to be used
as a reference measure only to aid in promoting reasonable driving: it should not be used in anticipation
of the use or operation of vehicles, machinery, or equipment. The analyzer makes no references whatsoever
to blood alcohol contents or other such measures of intoxication promulgated by government, medical,
or other agencies or bodies.
|
|
|
|
SPECIFICATION |
- Power Source : Two "AAA" batteries
- Battery Life : More than 800 measurement
- Sensor Type : MEMS Semiconductor Gas Sensor
- Dimensions : 90 x 30 x 17 (mm)
- Weight : 43g (Including Batteries)
|
|
|
|
CARE |
Keep the Breath Analyzer dry; if it gets wet,
wipe it dry immediately. Use and store the Breath
Analyzer only in normal temperature environments.
Handle the Breath Analyzer carefully; do not drop
it. Keep the Breath Analyzer away from dust and dirt,
and wipe it with a damp cloth occasionally to keep
it looking new.
Modifying or tampering with the analyzer’s internal
components can cause a malfunction and might invalidate
its warranty.
|
|
|
|
|
|
|
|
|
|
|
|
|